Add to Cart
For many years, electrical conductors made of aluminum wire have been in use. Aluminum wire was first used for power transmission lines by electrical utilities not long after the construction of modern power distribution networks in the late 1880s. For over a century, aluminum has been utilized in electrical applications in the US in a safe and efficient manner.
Chem ical Com ponents (%) | ||||||||||||||
Type | Si | Fe | Cu | Mn | Mg | Cr | Ni | Zn | Ti | Zr | Other | Al | ||
per | Toal | |||||||||||||
1350 | 0.1 | 0.4 | 0.05 | 0.01 | - | 0.01 | - | 0.05 | 0.03 Ga, 0.05B 0.02 V+Ti | - | - | 0.03 | 0.1 | 99.5 |
1370 | 0.1 | 0.25 | 0.02 | 0.01 | 0.02 | 0.01 | - | 0.04 | 0.03 Ga, 0.02B 0.02 V+Ti | - | - | 0.02 | 0.1 | 99.7 |
1A60 | 0.1 | 0.25 | 0.01 | - | - | - | - | - | - | 0.02 R+Ti +Mn+Gr | - | 0.03 | - | 99.6 |
Conductivity and Strength Tens ile | |||||
Type | Conductivity (20ºC)/O·m <= | Conductivity (20ºC)/%IACS >= | Strength Tens ile Mpa | Elongation/% (200m m gauge length) >= | |
1350 | 0 | 27.9 | 61.8 | 60-95 | 25 |
H12 | 28.03 | 61.5 | 85-115 | 12 | |
H13 | 28.08 | 61.4 | 105-135 | 10 | |
H14 | 28.12 | 61.3 | 120-150 | 8 | |
1370 | 0 | 27.9 | 61.8 | 60-95 | 25 |
H12 | 28.01 | 61.55 | 85-115 | 11 | |
H13 | 28.03 | 61.5 | 105-135 | 8 | |
H14 | 28.05 | 61.47 | 115-150 | 5 | |
H16 | 28.08 | 61.4 | 130-160 | 5 | |
1A60 | 0 | 27.55 | 62.68 | 60-90 | 25 |
H12 | 27.85 | 61.91 | 80-110 | 13 | |
H13 | 28.01 | 61.55 | 95-115 | 11 | |
H14 | 28.01 | 61.55 | 110-130 | 8 | |
H16 | 28.01 | 61.55 | 120-150 | 5 |
Purity | Chemical Composition% | |||||
AL Minimum | Foreign Content,Maximum | |||||
Si | Fe | Cu | V+Cr+Mn+Ti | Other | ||
Al99.60E | 99.6 | 0.08 | 0.20 | 0.005 | 0.01 | 0.3 |
Type | Tensile Strength,N/mm² | Fracture Toughness%,Min | Electrical Resistance Ωmm²/m 20,Max |
A | 60-80 | 25 | 0.02755 |
A2 | 80-110 | 12 | 0.02785 |
A4 | 95-115 | 10 | 0.02801 |
A6 | 110-130 | 8 | 0.02801 |
A8 | 120-150 | 6 | 0.02801 |
Temper | Tensile Strength | |
Ks j | M pa | |
1350-O | 8.5-14.0 | 59-97 |
1350-H12 and-H22 | 12.0-17.0 | 83-117 |
1350-H14 and-H24 | 15.0-20.0 | 103-138 |
1350-H16 and-H26 | 17.0-22.0 | 117-152 |
Temper | Resistivity | Equivalent Volume Conductivity,% |
Max.Ω.mm2/m | IACS Min. | |
1350-O | 0.027899 | 61.8 |
1350-H12 and-H22 | 0.028035 | 61.5 |
1350-H14 and-H24 | 0.028080 | 61.4 |
1350-H16 and-H26 | 0.028126 | 61.3 |